Poor ink/water balance.
Set ink/water to minimum.
______________________________________________________________________
Improper fountain solution concentration.
Set solution to proper dosage.
______________________________________________________________________
Condition of dampening system.
Reset and clean system.
______________________________________________________________________
Loss of image area.
Check for plate wear.
*The solutions provided from the troubleshooting guide are general in nature, please contact your sales or technical representative to discuss specific issues.